Scientific and Technical Journal

ELECTROTECHNIC AND COMPUTER SYSTEMS

ISSN Print 2221-3937
ISSN Online 2221-3805
SYNTHESIS OF ACTIVE SHIELDING FEED-FORWARD SYSTEM OF TECHNOGENIC POWER FREQUENCY MAGNETIC FIELD INTO THE SET AREA OF SPACE
Abstract:

The method of power frequency technogenic magnetic fields active screeningin feed-forward system synthesis into the set area of space using controlled magnetic fields is reduced to solving a nonlinear programming problem, in which calculation of goal function and constraints based on the Bio-Savar-Laplace low.

Authors:
Keywords
DOI
10.15276/etks.15.91.2014.96
References

1. Active Magnetic Shielding (Field Cancellation), http://www.emfservices.com/afcs.html. (In English)

2. Beltran H., FusterV., and García M., (2005), Magnetic Field Reduction Screening System for a Magnetic Field Source used in Industrial Applications, 9º Congreso Hispano Luso de Ingeniería Eléctrica (9CHLIE), Marbella (Málaga), pp. 84 – 99 (In English).

3. Celozzi S., and Garzia F., (2004), Active Shielding for power-frequency Magnetic Feld Reduction using Genetic Algorithms Optimization, IEE Proc. Sci. Meas, Technol, Rome, Italy, Vol. 151, No. 1, pp. 2 – 7 (In English).

4. Brake H.J.M., WieringaH.J.,and Rogalla H., (1991),Improvement of the Performance of a mu-metal Magnetically Shielded Room by Means of Active Compensation (Biomagnetic Applications), Measurement Science and Technology, Vol. 2 (7), 596 p. (In English).

5. Yamazaki K. Kato K., and KobayashiK., (2004), MCG Measurement in the Environment of Active Magnetic Shield, Neurology and Clinical Neurophysiology, Vol. 40, pp. 1 – 4 (In English).

6. Schnabel A., Voigt J. Burghoff M., and Knappe-Gruneberg S., (2003), Magnetic Shielding State of art, new Magnetic Shielding and Active Magnetic Shielding for Low noise Applications, Rome, Italy, Vol. 51, No. 5, pp. 137 – 142 (In English).

7. Shenkman A., Sonkin N., and Kamensky V., (2005), Active Protection from Electromagnetic Field Hazards of a high Voltage Power Line, HAIT Journal of Science and Engineering B, Vol. 2, No. 2, pp. 254 – 265 (In English).

8. Brake H.J.M. R. Huonker, and H. Rogalla, (1993), New Results in Active noise Compensation for Magnetically Shielded Rooms, Meas. Sci. Technol, No. 4, pp. 1370 – 1375 (In English).

9. Kato, Kazuo, Yamazaki, Keita, Sato, Tomoya, Haga, Akira, Okitsu, Takashi, Muramatsu, Kazuhiro, Ueda, Tomoaki, Yoshizawa,and Masahito,(2005),Shielding Effect of Panel Type Active Magnetic Compensation, IEEJ Transactions on Fundamentals and Materials,Tokyo,Vol. 125, pp. 99–106(In English).

10. Rozov V.Y., and Assyirov D.A. Metod aktivnogo ekranirovaniya vneshnego magnitnogo polya tehnicheskih ob'ektov [Method of External Magnetic field Active Shielding of Technical Objects], (2006), Tekhnichna Elektrodynamika, Kiev, Ukraine, Vol. 3, pp. 13 – 16 (In Russian).

11. Rozov V.Y., Assyirov D.A., and Reytskiy S.Y. Zamknutyie sistemyi kompensatsii magnitnogo polya tehnicheskih ob'ektov s razlichnyimi sposobami formirovaniya obratnyih svyazey [Technical Objects Magnetic-field Closed loop Compensation Systems with Different feed-backs Forming], (2008), Tekhnichna Elektrodynamika, Kiev, Ukraine, Vol. 4, pр. 97 – 100 (In Russian).

Published: