Abstract:

The results of the study starting and braking modes unregulated asynchronous electric pumps obtained by mathematical modelling. The analysis of transient modes of induction motor pump in case of direct run induction motor, using the method of winding switching from star to delta and using your smooth start induction motor pump. Brought in article analyses the survey results starting and braking modes of asynchronous electric pump demonstrate the effectiveness of the use of the most common ways to run smooth induction motor pump to eliminate vibrations electromagnetic torque of the engine, leading to the appearance of water hammer in water supply and sanitation, reducing inrush current induction motor.

Authors:
Keywords
DOI
10.15276/etks.15.91.2014.38
References
  1. Vasilyev D.S. Issledovanie elektromekha-nicheskikh protsessov pri pryamom puske i tormozhenii asinkhronnykh dvigatelei s uchetom peremennykh parametro [Analysis of Electro-mechanical Transients for Squirrel-Cage Induction Motor Direct Starting and Braking with Allowance for Variable Parameters and Transients Comparison with soft Starting and Braking Ones],(2010), Transactions of Kremenchuk Mykhailo Ostrohradskyi National University Publ., No. 4(60),Chast'1,pp. 43–49. (In Russian).
  2. Kalinov A.P.,Yukhimenko M.Y., and Isaev S.V. Issledovanie effektivnosti formirovaniya puskovikh rezhimov asinkhronnogo dvigatelya [Investigation of the Efficiency Formation of the Induction Motor Starting Modes],(2007)Electromechanical and Energy Systems Publ.; Vol.2(2), pp. 15–20.
  3. Kostishin V.S., andKurljak P.O. Modeljuvannja rezhimіv roboti elektroprivodnih magіstral'nih nasosnih agregatіv іz zastosuvannjam avtomatizovanoї sistemi plavnogo pusku [Modeling of Modes of Motor-Driven Mainline Pump Units Using Automated System with Soft Starter], (2013), Naukovі Pracі Donec'kogo Nacіonal'nogo Tehnіchnogo Unіversitetu Publ., No. 1 (14), pp. 129 – 134 (InUkrainian).
  4. Kurljak P.O. Bond Graph modeljuvannja elektromehanіchnih perehіdnih procesіv pіd chas pusku nasosnih agregatіv magіstral'nih naftoprovodіv na vіdkritu zasuvku [Bond Graph Modeling of Electromechanical Transients During Start Pumping units for oil Pipelines Open Latch], (2012), Zbіrnik Materіalіv X Mіzhnarodnoї Naukovo-tehnіchnoї Konferencії Molodih Uchenih ta Specіalіstіv “Elektromehanіchnі ta Energetichnі Sistemi, Metodi Modeljuvannja ta Optimіzacії”Publ. Kremenchuk Ukraine, pp.132–133 (InUkrainian).
  5. PlahtynaE.G. Matematicheskoemodelirovanieelektromashinno-ventil'nykhsistem [MatematicheskoeModelingElectromachine-valveSystems, (1986) L'vov. UniversityPubl.,161 p. (InRussian).
  6. Petrov L.P. Upravlenie puskom i tormozheniem asinkhronnykh elektrodvigatelei [Control of Start-up and Braking Asynchronous Electric Motor], (1981), JenergoizdatPubl, Moscow, RussianFederation. 184 p. (InRussian).
  7. Tingjian Zhong, Li Zhu, and Minghua Zhou,(2009),Study on the Simulation of the Soft Start of the Asynchronous Motor with Pump Control Function Based on Thyristor Modern Applied Science,Vol 3, No. 5, pp. 112 – 117.
  8. Xu Liaosong, Qian Cunyuan & Xie Weida, (2001), A Soft-stop Control Method of Asynchronous Motor Soft-starter.Power Electronics, No. 35(3),pp. 41 –44.
  9. Zenginobuz G., Cedircil, Ermis, M, and Barlark C., (2000), Soft Starting of Large Induction Motors at Constant Current withMinimized Starting Torque Pulsations,Conference Re Cordofthe2000 IEEE. No.3(11), pp.1593 – 1604.
  10. Zhang Xueping, (2005), Application of Single-chip Microcomputer in Soft Start of AC Motor. Industry and MineAutomation,No.4, pp. 19 – 21.