PROPORTIONALLY-INTEGRAL REGULATOR WITH DOUBLE INTEGRATION
Abstract:

The problem of influencing of negative internal feed-back on electromotive force of engine of direct current on the process of adjusting of current in the contour of adjusting of the current adjusted on a module optimum is examined. It is suggested in place of proportionally-integral regulator of current to use a proportionally-integral regulator with double integration of signal of error on a current. The comparative static and dynamic error of work of contour of current analysis with both regulators is conducted.

Authors:
Keywords
DOI
References

1. Gerasymiak R.P Improving the quality of automatic control systems. Textbook. allowance. – Kiev: UMK VO, 1992.– - 100. [in Russian].

2. Kliuchevoj V.I The theory of electric. Textbook for high schools. – Moscow: Energo Atomizdat, 1985. – 560. [in Russian].

3. Freire F, Orttenburger F. Introduction to control electronic devices. / Per. with it. – Moscow: Energiya, 1973. – 192 р. [in Russian].